top of page

Main Kitchen Drawing for Hotel and Restaurant: Complete Layout with All Essential Sections

  • Writer: admin
    admin
  • 15 hours ago
  • 2 min read

A well-planned main kitchen drawing is the foundation of efficient hotel and restaurant operations. The kitchen should be designed to ensure smooth workflow, food safety, hygiene, and maximum productivity. A professional kitchen layout includes dedicated sections for different cuisines and support areas to avoid cross-contamination and improve service speed.


Detailed Main Kitchen Layout for a 50-Room Hotel / 100-Cover Restaurant

Recommended Kitchen Size

  • Total Kitchen Area: 2,500–3,000 sq. ft.

  • Restaurant Seating Capacity: 100 Covers

  • Banquet Support: Up to 150 Guests

  • Kitchen Width: 50 ft

  • Kitchen Length: 60 ft


Kitchen Flow Diagram

────────────────────────────────────────────────────────────
                     GOODS RECEIVING AREA
                           10' x 10'
────────────────────────────────────────────────────────────
│ Dry Store │ Veg Store │ Chiller │ D-Freezer │ 4-Door Freezer │
│ 10'x10'   │ 8'x10'    │ 8'x10'  │ 6'x8'     │ 8'x8'          │
────────────────────────────────────────────────────────────
                          PREP AREA
────────────────────────────────────────────────────────────
│ Veg Prep │ Non-Veg Prep │ Fresh Area │ Butchery │
│ 10'x10'  │ 10'x10'      │ 8'x10'     │ 8'x8'    │
────────────────────────────────────────────────────────────

              MAIN COOKING PRODUCTION AREA
────────────────────────────────────────────────────────────
│ TANDOOR │ INDIAN │ CHINESE │ SOUTH INDIAN │ CONTINENTAL │
│ 12'x12' │12'x15' │10'x12'  │10'x10'       │10'x12'      │
────────────────────────────────────────────────────────────

  Tandoor Oven (2)
  Curry Range (4 Burner)
  Stock Pot Range
  Chinese Wok Range
  Dosa Plate
  Idli Steamer
  Salamander
  Griddle
  Fryer

────────────────────────────────────────────────────────────
                PASS / PICKUP COUNTER
                     20' x 6'
────────────────────────────────────────────────────────────
      HOT BAIN MARIE | KOT DISPLAY | HEAT LAMPS
────────────────────────────────────────────────────────────

             CHEF OFFICE & SUPERVISION AREA
────────────────────────────────────────────────────────────
│ Chef Cabin │ Admin Desk │ Recipe Library │
│ 10'x10'    │             Fresh Air View   │
────────────────────────────────────────────────────────────

                UT / KST (STEWARDING)
────────────────────────────────────────────────────────────
│ Pot Wash │ Dish Wash │ Glass Wash │ Waste Room │
│ 10'x10'  │ 10'x10'   │ 8'x8'      │ 8'x8'      │
────────────────────────────────────────────────────────────

                  STAFF FACILITIES
────────────────────────────────────────────────────────────
│ Staff Lockers │ Uniform Room │ Staff Toilet │
────────────────────────────────────────────────────────────

Equipment Placement Chart

Kitchen area allocation

Suggested space distribution for a 3,000 sq. ft. hotel kitchen.

02505007501,000Main CookingPreparation AreaStorage & FreezersStewarding UT/KSTPickup CounterChef CabinStaff FacilitiesCirculation Space


Exhaust & Fresh Air Ducting Layout

Type-I Exhaust Hood Coverage

  1. Tandoor Section – 12 ft Hood

  2. Indian Range – 15 ft Hood

  3. Chinese Wok Station – 12 ft Hood

  4. South Indian Dosa Station – 10 ft Hood

  5. Continental Range – 10 ft Hood

  6. Frying Station – 8 ft Hood


Fresh Air Supply

  • Fresh Air Handling Unit (FAHU): 8,000–10,000 CFM

  • Positive pressure maintained in kitchen.

  • Fresh air diffusers above prep areas.

  • Exhaust fans mounted on rooftop.


Utility Requirements

Utility

Requirement

LPG Bank

Outside Building

Gas Pipeline

SS 304 Grade

Water Connection

Hot & Cold

Floor Drain

Every 8 ft

Grease Trap

Near Pot Wash

Electrical Load

80–100 KW

Exhaust Capacity

20,000–25,000 CFM

Recommended Kitchen Workflow

Receiving → Storage → Preparation → Cooking → Pickup Counter → Restaurant Service → UT/KST Washing → Waste Disposal


This workflow minimizes cross-contamination, improves productivity, and complies with hotel and restaurant operational standards for a 50-room hotel or 100-cover restaurant.


 
 
 
bottom of page